ZTI Communications offers several NTP and PTP time servers with a wide range of operating temperatures in a compact and robust enclosure with different options described in the following table.

ProductProtocolSatellitesApplicationOperating temperaturePower-over-EthernetFast start without satellites (1)Oscillator (2)
z504NTPGPSStatic & Mobile0°C | +50°COptionNoTCXO
z505NTPGPSStatic & Mobile- 40°C | + 70°C
OptionOptionOCXOHR
z506NTPGNSSStatic & Mobile- 40°C | + 70°C
OptionOptionOCXOHR
z510NTP + PTPGPSStatic- 40°C | + 70°COptionNoOCXOHR

Notes
(1) Fast start without satellites: with this feature the unit needs less than one minute to provide accurate timing information
(2) OCXOHR: OCXO High Resolution

These time servers are industrially proven and used in many countries for different types of civil and military applications: defence, aerospace, communication systems, data centers, financial networks, utilities, factory automation, security …

Click below to view the z500 datasheets for more information.

z504 datasheet
z505 datasheet
z506 datasheet
z510 datasheet
 
z504High Precision NTP Time Server synchronized by GPS for Static and Mobile Applications / GPS Master Clock with PoE and advanced Input/Output features (Indoor or Outdoor use).
Operating temperature range: 0°C to +50°C
z505High Precision NTP Time Server synchronized by GPS for Static and Mobile Applications / GPS Master Clock with PoE, Fast start and Advanced Input/Output features (Indoor or Outdoor use).
Operating temperature range: -40°C to +70°C
z506NTP Time Server Multi-GNSS primary clock for Static and Mobile Applications / GNSS Master Clock with PoE, Fast start and Advanced Input/Output features (Indoor or Outdoor use).
Operating temperature range: -40°C to +70°C
z510M (Master)PTP/IEEE 1588 Grandmaster Clock and NTP Time Server with high accuracy GPS receiver for Static Applications.
Operating temperature range: -40°C to +70°C
z510C (Client)IEEE 1588 / PTP Client with pulse generator, IRIG output, and event input.
Operating temperature range: -40°C to +70°C

Option: Fast Start feature (z505 and z506 products)

With the “Fast Startfeature the unit needs less than 1 minute at power-up to provide accurate timing information. And if it has already GPS(GNSS) Almanac and Ephemeris loaded in memory, then it is fully operational in about 20 seconds.

Then it becomes possible to power-up the unit only a few minutes per day, to synchronize the different elements of your system.

To provide the time at power-up if no GPS (GNSS) signal is available (antenna disconnected or hidden inside a building for example) and if no synchronization is possible with other external time servers (private or public), the internal RTC with TCXO powered by internal lithium battery delivers time during at least 6 months (when power OFF), with 1ms to 100ms accuracy:

  • max drift of ±4 minutes/Year with the temperature range -40°C to +70°C.
  • max drift of ±1 minute/Year with the temperature range 0°C to +50°C.

Specifications are subject to change without notice.

 
Need of a USB GNSS dongle? Use the z052 USB GNSS dongle with PPS.